Machinability Assessment of Titanium Alloy Ti-6Al-4V for Biomedical Applications

Article Preview

Abstract:

Titanium alloy (Ti-6Al-4V) has a wide range of application in various fields of engineering. Titanium is mainly used to manufacture aerospace components like landing gear, fuselage, wings, engines etc. and biomedical components like hip joint, knee joint, dental implants etc. Titanium has outstanding material properties such as corrosion resistance, fatigue strength, tensile strength and a very good biocompatibility which makes this material very alluring for biomedical applications. Contrary, the machinability of the material is problematic because of the phase transformations and thus, titanium alloy is a challenge for machining operation. This research is a comparative analysis between the implants manufactured by traditional method of casting and machining. The femoral stem of the hip joint replacement is designed and the component is machined using a five-axis CNC machine. The machined component was subjected to surface roughness testing, tensile testing and bulk hardness testing. The values were compared with the values of titanium implants manufactured by casting.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 941-944)

Pages:

1985-1990

Citation:

Online since:

June 2014

Export:

Price:

* - Corresponding Author

[1] Mitsuo Niinomi, Recent research and development in titanium alloys for biomedical application and health care goods, Science and technology of advanced materials, (2008).

Google Scholar

[2] 2.M. Geetha, A. K. Singh, R. Asokamani, A. K. Gogia, Ti based biomaterials, the ultimate choice for orthopaedic implants, Progress in material science, (2009).

DOI: 10.1016/j.pmatsci.2008.06.004

Google Scholar

[3] Marc Long, H. J. Rack, Titanium alloys in total joint replacement- a material science perspective, Biomaterials, (1998).

Google Scholar

[4] Carlos Oldani, Alejandro Dominguez, Ti as biomaterial for implants, Biomaterials, (2007).

Google Scholar

[5] H.J. Rack, J.I. Qazi, Titanium alloys for biomedical application, Material science and engineering, (2005).

Google Scholar

[6] Ahmet Hascalik, Farnaz Nourbakhsh, K. P. Rajurkar, A. P Malshe, Wire electro discharge machining of titanium alloy, Biomanufacturing, (2013).

DOI: 10.1016/j.procir.2013.01.003

Google Scholar

[7] Tengvall P, Lundstrom I (1992), Physico chemical consideration of titanium as a biomaterial, Clin materials, vol-9: 115-134.

Google Scholar

[8] Burhanuddin Y, Che Haron C. H, Ghani J A, Ariffin A K, Ibrahim G A, Yasir A, El-Maghribi N H (2008).

Google Scholar

[9] Matej Balazic, Janez Kopac, Machining of titanium alloy for biomedical application, Journal of mechanical engineering, (2010).

Google Scholar

[10] Mrudula. S, Kulkarni, S. R. Sathe, Experimental determination of material properties of cortical cadaveric femur bone, Journal of biomechanics, (2008).

Google Scholar

[11] Luc a Cristofolini, Marco Viceconti, Angelo Cappello, Mechanical validation of whole bone composite femur models, Journal of biomechanics, (1996).

DOI: 10.1016/0021-9290(95)00084-4

Google Scholar

[12] A. Rohlmann, U. Mossner, G. Bergmann, Finite element analysis and experimental investigation of stress in a femur bone, Journal of biomedical engineering, (1982).

Google Scholar

[13] B. R. Rawal, Rahul Ribeiro, Rajesh Malhotra, Naresh Bhatnagar, Design and manufacturing of femoral stem for Indian population, Journal of manufacturing process, (2012).

DOI: 10.1016/j.jmapro.2011.12.004

Google Scholar

[14] J. A. Simoes, A.T. Marques, Design of a composite hip femoral prosthesis, Material and design, (2005).

Google Scholar