Serum cystatin C as a measure of GFR in renal transplant patients

Jovanović Dijana B. (Nefrološka klinika, Klinički centar Srbije, Beograd)
Krstivojević Pavle (Zdravstveni centar, Valjevo)
Obradović Ivana (Institut za medicinsku biohemiju, Klinički centar Srbije, Beograd)
Đurđević Vesna (Institut za medicinsku biohemiju, Klinički centar Srbije, Beograd)
Blagojević-Lazić Radmila (Institut za medicinsku biohemiju, Klinički centar Srbije, Beograd)
Đukanović Ljubica D. (Nefrološka klinika, Klinički centar Srbije, Beograd)

INTRODUCTION Assessment of renal function is of great importance in clinical medicine, especially in renal transplant patients requiring frequent controls of renal function. Therefore, continuous efforts have been made in searching precise and simple method for determination of glomerular filtration rate (GFR). Serum level of cystatin C (CyC), protein of low molecular weight, has been proposed as measure of GFR, but the data of its value in renal transplant patients are scarce [8-10]. PURPOSE The aim of this study was to compare the serum levels of low molecular weight proteins CyC and ß2-microglobulin (ß2-MG) with creatinine clearance, as well known measure of GFR, in renal transplant patients and control group of patients with different renal disease. PATIENTS AND METHODS The study included 36 patients divided into two groups. Group 1: 20 renal transplant patients (12 men and 8 women) aged between 22 and 63 (40.4±10.1) years with creatinine clearance from 7.1 to 77.7 ml/min. Group 2: 16 controls (5 men and 11 women) with various renal diseases, aged between 24 and 63 (41.5±12.5) years with creatinine clearance from 60.5 to 116.8 ml/min. N Latex Cystatin C and ß2-microglobulin for the Behring Nephelometer System was used in this study. Creatinine was determined with Jaffe-reaction in serum and urine. RESULTS In renal transplant patients as well as in control group of patients the significant correlation between creatinine clearance and reciprocal values of the serum CyC (rt=0.828; pt<0.001; rc=0.603; pc<0.05) and reciprocal values of the serum ß2-MG levels (rt=0.791; pt<0.001; rc=0.627 pc<0.05) was found (Graph 1). There was a slightly better correlation between creatinine clearance and reciprocal values of the serum CyC than the one between creatinine clearance and reciprocal values of the serum ß2-MG without statistical significance in renal transplant patients. There was no difference in correlation coefficients between both low molecular weight proteins and creatinine clearance in Group 2. The correlation coefficient between serum CyC and ß2-MG was r=0.839(p<0.001)in renal transplant patients and r=0.835 (p<0.05) in control group. There were no significant differences in correlation coefficients between reciprocal values of serum CyC and creatinine clearance (p=0,2043) as well as reciprocal values of serum ß2-MG and creatinine clearance (p=0.3717) between Group 1 and Group 2. DISCUSSION In renal transplant patients rapid assessment of graft function is necessary. This allows early recognition of rejection as well as differential diagnosis of different renal graft disorders. Study of Risch and co [16] suggested that serum CyC was very good marker for GFR in renal transplant patients which was confirmed by the other authors too [20-22]. During inflammatory process or other pathological conditions, especially during acute rejection or infections, CyC also provided precise assessment of GFR while creatinine clearance varied dramatically [16], Serum concentration of ß2-MG, another low molecular weight protein, also depends both on its production rate and the GFR [5,19]. Its production is dramatically different in patients with infections [5] as well as while immunosuppressive drugs are used [16], Therefore, ß2-MG is impractical as GFR marker in patients with renal transplants. So, serum CyC was considered as better marker for GFR than ß2-MG and creatinine clearance in renal transplant patients with different complications [16], In this study serum CyC was slightly better marker for GFR than ß2-MG, without statistical significance (Graph 1). Renal transplant patients, however, were in the stable condition at the time of the study. CONCLUSION Serum CyC was moderately better marker of GFR than ß2-MG in renal transplant patients when they were in the stable condition. Serum CyC and ß2-MG were the same markers of GFR in control group of patients with various renal diseases. There was no significant difference in correlation coefficients between reciprocal values of the serum CyC and creatinine clearance (p=0.2043) as well as reciprocal values of the serum ß2-MG levels and creatinine clearance (p=0.3717) between two examined groups of patients. The studies on renal transplant patients with acute graft rejection or infections are warranted.

Keywords: cystatin C, ß2-microglobulin, measure of glomerular filtration rate (GFR), renal transplant patients