Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter March 3, 2014

List-mode reconstruction in 2D strip PET

  • Piotr Białas , Jakub Kowal , Adam Strzelecki EMAIL logo , Tomasz Bednarski , Eryk Czerwiński , Krzysztof Giergiel , Łukasz Kapłon , Andrzej Kochanowski , Grzegorz Korcyl , Paweł Kowalski , Tomasz Kozik , Wojciech Krzemień , Marcin Molenda , Ines Moskal , Paweł Moskal , Szymon Niedźwiecki , Marek Pałka , Monika Pawlik , Lech Raczyński , Zbigniew Rudy , Piotr Salabura , Neha G. Sharma , Michał Silarski , Artur Słomski , Jerzy Smyrski , Konrad Szymański , Wojciech Wiślicki , Piotr Witkowski , Marcin Zieliński and Natalia Zoń

Abstract

Using a theory of list-mode maximum likelihood expectation-maximization (MLEM) algorithm, in this contribution, we present a derivation of the system response kernel for a novel positron emission tomography (PET) detector based on plastic scintillators.


Corresponding author: Adam Strzelecki, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, Reymonta 4, Room 05A, 30-059 Cracow, Poland, E-mail:

Acknowledgments

We acknowledge the technical and administrative support by M. Adamczyk, T. Gucwa-Ryś, A. Heczko, K. Łojek, M. Kajetanowicz, G. Konopka-Cupiał, J. Majewski, and W. Migdał and the financial support by the Polish National Center for Development and Research and by the Foundation for Polish Science through MPD program, the EU and MSHE Grant No. POIG.02.03.00-00-013/09.

References

1. Shepp LA, Vardi Y. Maximum likelihood reconstruction in positron emission tomography. IEEE Trans Med Imaging 1982;MI-1:113–22.10.1109/TMI.1982.4307558Search in Google Scholar PubMed

2. Shepp LA, Vardi Y, Kaufman L. A statistical model for positron emission tomography. J Am Stat Assoc 1985;80:8–20.10.1080/01621459.1985.10477119Search in Google Scholar

3. Moskal P, Salabura P, Silarski M, Smyrski J, Zdebik J, Zieliński M. Novel detector systems for the positron emission tomography. Bio-Algorithms Med-Syst 2011;7:73.Search in Google Scholar

4. Moskal P, Bednarski T, Białas P, Ciszewska M, Czerwiński E, Heczko A, et al. Strip-PET: a novel detector concept for the TOF-PET scanner. Nucl Med Rev C 2012;15:68–9.Search in Google Scholar

5. Moskal P, Bednarski T, Białas P, Ciszewska M, Czerwiński E, Heczko A, et al. TOF-PET detector concept based on organic scintillators. Nucl Med Rev C 2012;15:81–4.Search in Google Scholar

6. Parra L, Berret HH. List-mode likelihood EM algorithm and noise estimation demonstrated on 2D-PET. IEEE Trans Med Imaging 1998;17:228–35.10.1109/42.700734Search in Google Scholar PubMed PubMed Central

7. Berret HH, White T, Parra L. List-mode likelihood. J Opt Soc Am A Opt Image Sci Vis 1997;14:2914–23.10.1364/JOSAA.14.002914Search in Google Scholar PubMed PubMed Central

Received: 2013-10-29
Accepted: 2014-1-7
Published Online: 2014-3-3
Published in Print: 2014-3-31

©2014 by Walter de Gruyter Berlin/Boston

Downloaded on 24.4.2024 from https://www.degruyter.com/document/doi/10.1515/bams-2013-0111/html
Scroll to top button